Infinity REU-VR3237WG /HD250e REU-VRM3237WC - 15 - Issue 1 - 19/05/09 ©Rinnai
12. Diagnostics Points
FLOW
CHART
No.
COMPONENT
MEASUREMENT POINT
CN
WIRE COLOUR
NOTE
1
SURGE PROTECTOR
AC207264V
DC1113V
Bk-Bk
WATER CONTROLLER
4
DC1113V
R-Bk
G
3
WATER FLOW SENSOR
5
6
P-P
E
2
Y-Bk
DC47VPULSE17460Hz
R-Bk
DC645V
6781Ω
DC215V
MODULATING VALVE
WATER FLOW
CONTROL DEVICE
Gy-Br
Gy-Y
R-B
BELOW DC1V(LIMITER ON)
DC1113V
DC46VLIMITEROFF
FULL OPEN POSITION
DC1113V
Gy-O
OPERATE ELECTRICITY
BELOW DC1V(LIMITER ON)
DC46VLIMITEROFF
ON2.7l/MIN (30Hz)
OVER 1800PULSE/MIN
GND
D
1
B-Br
A
1
COMBUSTION FAN
7
Y-BODY EARTH
AC5150V
OVERDC1μA
AFTER IGNITION
FLAME ROD
E
1
8
OFF2.0l
/MIN
20Hz
BELOW 1200PULSE/MIN
G
6
33400Hz
H
1
Br-W
O-W
Y-W
R-W
DC12VOPERATINGDC26V
1535Ω
GND
3
2
17
BY-PASS FLOW
CONTROL DEVICE
NORMAL VALUE
CONTROL ELECTRICITY
FULL CLOSE POSITION
FLAME CONDITION
B
1
GND
W-Bk
Y-Bk
DC1113V
DC645V
Y-FLAME ROD
Gy-Gy
C
1
IGNITER
P-Bk
MAIN SOLENOID VALVE
R-Bk
F
2
THERMAL FUSE
G
1
R-R
W-W
G
5
W-P
AC207264V
DC1113V
O-Bk
BELOW1Ω   
9
13
14
15
16
15°C 114 140kΩ
30°C… 64〜 78kΩ
45°C… 36〜 45kΩ
60°C… 22〜 27kΩ
105°C… 06〜 08k
Ω
F
1
F
3
OUTGOING THERMISTOR
G
4
F
4
Y-Bk
DC1113V
17
DC1113V
DC1113V
HEAT EXCHANGER
OUTGOING THERMISTOR
SOLENOID VALVE 1
SOLENOID VALVE 2
SOLENOID VALVE 3
E
3
12
W-W
10
3541Ω
3743Ω
3743Ω
3743Ω

Other manuals for Rinnai REU-VRM3237WC

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rinnai REU-VRM3237WC and is the answer not in the manual?

Rinnai REU-VRM3237WC Specifications

General IconGeneral
BrandRinnai
ModelREU-VRM3237WC
CategoryWater Heater
LanguageEnglish

Related product manuals