16
1. Cycle hydraulic system to ensure all air has been purged.
2. With unit in transport position, inspect wing cam lock—look for space between hook and cam roller.
3. If hook is not in contact with cam roller—adjust the cylinder clevis.
4. A) Remove cylinder clevis pin.
B) Loosen cylinder clevis lock screw.
C) Turn cylinder clevis CCW 1/2 to 1 turn.
D) Re-install cylinder clevis to wing lock.
Check for space here;
- If hook is in contact with cam roller
then cylinder setting is OK.
- If you can see a space then cylinder
requires setting.
Adjust cylinder clevis as necessary