Details the two sets of assembly and installation instructions provided for the cooling unit.
Mentions that the declaration of conformity is supplied as a separate document.
Emphasizes that instructions are integral to the product and must be given to the plant operator.
Explains symbols for instructed actions, danger, caution, and notes.
Provides essential safety guidelines for assembly, installation, servicing, and operation of the unit.
Explains the purpose of enclosure cooling units in dissipating heat and protecting components.
Details the refrigeration cycle, including evaporator, compressor, condenser, and expansion valve.
Describes the Basic and Comfort controllers used for setting cooling unit functions.
Explains master-slave connection for up to ten cooling units via serial interface X2.
Covers pressure switches, temperature monitoring, thermal winding shields, and system message contacts.
Explains condensation formation and automatic evaporation processes.
Details the use, cleaning, and monitoring of filter mats for cooling unit condensers.
Describes the operation and benefits of a door limit switch for preventing condensation.
Information on connecting an interface card for higher-level monitoring systems.
Defines the intended use of cooling units and manufacturer liability for improper use.
Lists the items included in the delivery package for the cooling unit.
Provides guidelines for selecting a suitable location for enclosure cooling unit installation.
Covers checks for packaging damage, enclosure airtightness, and condensation prevention.
Advises on arranging components to ensure proper airflow and prevent condensation.
Details options for external, partial internal, and full internal mounting of the cooling unit.
Step-by-step guide for preparing the enclosure panel for cooling unit mounting.
Instructions for attaching the cooling unit to the outside of an enclosure panel.
Procedure for mounting the cooling unit partially inside the enclosure.
Detailed steps for installing the cooling unit fully inside the enclosure.
Explains how to connect the condensate hose and ensure proper routing.
General safety and regulatory requirements for electrical installation.
Specifies voltage, frequency, and connection requirements for the cooling unit.
Addresses measures for overvoltage protection and ensuring adequate supply line capacity.
Details electrical connection requirements specific to three-phase cooling units.
Notes and requirements for connecting the door limit switch to the unit.
Information regarding adherence to flicker limits and potential mitigation measures.
Recommendations for connecting a conductor for potential equalisation.
General guidance for performing the electrical installation work.
Instructions for connecting multiple cooling units using the serial interface X2.
Explains the use of interface card X3 for system evaluation and monitoring.
Guidance for installing the power supply and connecting system message relays.
Wiring diagrams for various RITTAL cooling unit models.
Explanation of symbols and component labels used in the electrical wiring plans.
Provides AC and DC contact data for various electrical components.
Steps to install filter media, fit the cooling unit, and set the filter mat monitor.
Safety warning before start-up and procedures for initial power-on and operation.
Instructions for operating the cooling unit via the Basic controller interface.
Lists voltage support, features, and operating modes of the Basic controller.
Explains the LED indicators and error codes for the Basic controller's status display.
Details how system messages are polled via floating contacts on the cooling unit.
Procedure to activate a test mode for the Basic controller to initiate cooling.
Instructions on how to adjust the temperature setting using the Basic controller.
Procedure for manually resetting the Basic controller after an alarm condition.
Instructions for operating the cooling unit via the Comfort controller interface.
Lists voltage support, features, and master-slave capabilities of the Comfort controller.
Procedure to activate a test mode for the Comfort controller to initiate cooling.
Overview of programming parameters, ranges, and tables for the Comfort controller.
Details configurable parameters, their ranges, factory settings, and descriptions.
Visual guide illustrating the sequence for programming parameters on the Comfort controller.
Explains how system messages are displayed and evaluated via relays.
Instructions for configuring identifiers (addresses) for master and slave cooling units.
Guidance on interpreting system messages displayed by the Comfort controller.
Table detailing system messages, causes, and recommended fault rectification measures.
Procedure to reset the Comfort controller after specific faults (A03, A06, A07).
General information on the cooling circuit's maintenance-free design and periodic cleaning needs.
Instructions for cleaning cooling unit components using compressed air for specific models.
Steps to disconnect the display connector during maintenance procedures.
Steps to disconnect fans, remove the cover, and remove the external fan.
Steps to remove the unit cover and disconnect earthing cables from chassis.
Initial steps for cleaning the heat exchanger coil and compressor chamber using compressed air.
Further steps for cleaning the heat exchanger coil and compressor chamber using compressed air.
Specific compressed air cleaning instructions for models SK 3328.xxx, SK 3329.xxx, SK 3332.xxx.
Instructions for removing louvred grilles and the infill panel from the unit.
Steps for pushing the display cable back through the cable gland during reassembly.
Procedure to loosen the screws securing the external circuit fan.
Steps to disconnect the earthing cables connected to the fan unit.
Steps to remove the unit cover and disconnect the main earthing cable.
Final steps for disconnecting the remaining earthing cables.
Final steps for cleaning the heat exchanger coil and compressor chamber.
Cautionary note regarding storage temperatures and upright positioning of the cooling unit.
General instructions for proper storage and environmentally sound disposal of the cooling unit.
Details found on the unit's rating plate, including technical specifications and approvals.
Instructions to observe mains connection data, voltage, frequency, and pre-fuse specifications.
Comprehensive table listing technical data for various RITTAL cooling unit models.
Exploded view and identification of spare parts for SK 3302.xxx models.
Exploded view and identification of spare parts for SK 3302.3xx models.
Exploded view and identification of spare parts for SK 3303.xxx and SK 3361.xxx models.
Exploded view and identification of spare parts for SK 3304.xxx and SK 3305.xxx models.
Exploded view and identification of spare parts for SK 3328.xxx and SK 3329.xxx models.
Exploded view and identification of spare parts for SK 3332.xxx models.
Exploded view and identification of spare parts for SK 3366.xxx and SK 3377.xxx models.
Information required when ordering spare parts, including unit model and fabrication number.
Diagrams showing cut-out and mounting dimensions for external installation of cooling units.
Diagrams showing cut-out and mounting dimensions for partial internal installation.
Diagrams showing cut-out and mounting dimensions for full internal installation.