11
Disconnect the High Voltage
Before you attempt to disconnect the high voltage by severing a cut loop, take note of the following safety
guidance:
DO
l Wear personal protective equipment (PPE) appropriate for electric vehicles.
l Use insulated tools.
Note: If an insulated tool is not available, avoid contact with the vehicle while cutting the loop.
DON'T
l Cut into or penetrate any other cables or
“Do Not Cut” locations.
l Touch any electrical cables.
l Touch electrical or battery components.
DON'T ATTEMPT IF
l
Cut loop (low-voltage) cables are inaccessible and can't be easily cut.
l Vehicle is on fire.
l Vehicle is in standing water or is submerged.
l You see a sign of potential fire, such as
l sparks
l detached cables
l increased temperature
l smoke or smell
l hissing, gurgling, or bubbling
l leaking fluid