3. SETTING FOR COMMUNICATION
IMAE02-E3
14
2. Press the shift key to change the display from character to set value.
3. Here, as an interval time of 250 ms needs to be set, calculate the interval time set value using the
equation.
For the equation, see the Equations for calculating interval time and interval time set
value (P. 13).
Interval time set value:
250 ms ÷ 1.666 ms 150 (Round to the nearest whole number.)
Interval time:
150 × 1.666 ms 249.9 (Approx. 250 ms)
Thus, enter an interval time set value of 150 calculated from the above by pressing the UP or
DOWN key at the front of the AE500.
4. Press the DOWN key to enter 0 in the lowest digit.