RKI GX-6000 User Manual

Default Icon
250 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
www.rkiinstruments.com
GX-6000
Operator’s Manual
Part Number: 71-0362
Revision: M
Released: 2/26/20

Table of Contents

Questions and Answers:

RKI GX-6000 Specifications

General IconGeneral
Detection Range (LEL)0-100% LEL
PumpInternal pump
Data LoggingYes
Range (H2S)0-100 ppm
Resolution (O2)0.1% vol
Resolution (LEL)1% LEL
Resolution (CO)1 ppm
Resolution (H2S)1 ppm
DisplayLCD with backlight
Gas Types DetectedO2, CO, H2S, LEL
CalibrationAutomatic or manual
AlarmsVisual, audible, and vibration alarms
Sensor TypeElectrochemical, catalytic
Range (O2)0 to 30% vol
Range (CO)0 - 500 ppm
Operating Temperature-20°C to 50°C
Humidity Range0% to 95% RH
CertificationsATEX, IECEx

Summary

Chapter 2: Description

Chapter 3: Operation

Startup and Initial Setup

Provides step-by-step instructions for starting up the GX-6000 unit.

Alarm Handling and Indications

Details alarm types, their indications, and how to respond.

Chapter 5: Calibration Mode

Calibration Preparation and Entry

Outlines the steps to enter calibration mode and required supplies.

Auto and Single Calibration Procedures

Provides instructions for performing auto and single calibration methods.

Bump Test Procedures

Details the procedure for performing a bump test on the instrument.

Chapter 7: Maintenance

Troubleshooting Common Issues

Provides solutions for common problems and error messages.

Appendix A: Maintenance Mode

Calibration and Bump Test Settings Management

Explains how to update calibration and bump test reminder settings.

Appendix C: Using the GX-6000 in Leak Check Mode

Leak Check Mode Startup and Operation

Details how to start and operate the GX-6000 in Leak Check Mode.

Leak Detection and Testing Procedures

Explains how to perform leak tests and manage alarms.

Appendix D: Using the GX-6000 in Bar Hole Mode

Bar Hole Mode Startup and Operation

Explains how to start and operate the GX-6000 in Bar Hole Mode.

Performing Bar Hole Tests

Details the procedure for conducting bar hole tests.

Appendix E: Using the GX-6000 in Inert Mode

Appendix F: ESS-03 Toxic Sensors

ESS-03 Calibration Procedures

Explains auto and single calibration for ESS-03 sensors.

Appendix G: Infrared Sensors

Appendix H: 10.0 eV/Benzene PID Sensor

Calibrating the 10.0 eV/Benzene PID Sensor

Provides instructions for calibrating the 10.0 eV/Benzene PID sensor.

Appendix I: 11.7 eV PID Sensor