Ultrasonic Flowmeter USM GT400
OPERATING INSTRUCTION
Reliable Measurement of Gas
Read the instructions before starting work!

Table of Contents

Other manuals for RMG USM GT400

Questions and Answers

  • D
    Denise LewisAug 1, 2025
    What to do if path errors occur in RMG USM GT400 Measuring Instruments?
    • S
      Stacey MillerAug 1, 2025
      Path errors in RMG Measuring Instruments can occur due to unsuitable operating conditions, contamination/condensation, or transducer/wiring malfunctions. To resolve this, consider the following: * Change the operating conditions or adapt the parameters to the desired mode of operation. * Check the wiring and plug connectors for contamination or condensation. * Have qualified personnel check for transducer or wiring defects and replace the transducer if needed.
  • B
    bonniewillisAug 17, 2025
    Why is the speed of sound at the limit values on my RMG USM GT400 Measuring Instruments?
    • P
      Paul DiazAug 17, 2025
      The speed of sound in RMG Measuring Instruments might be at limit values (± 500 m/s) because you are using a gas with a strongly deviating speed of sound or because strongly deviating speeds of sound are expected. A parameterization must be carried out. Alternatively, activate the 'Signal Tracking' function in AI-27 to adjust the speed of sound range of the evaluation window.

Summary

2 Brief instructions

2.3 Start Up

Guides users through the initial steps required to start up the device after installation and connection.

4 Functional principle - Ultrasonic flow measurement

4.1 General description

Explains the fundamental working principle of ultrasonic flow measurement, including formulas and path concepts.

5 Safety

5.1 Intended use

Defines the specific purpose and safe operating environment for the ultrasonic gas meter, including explosive areas.

5.3 Qualification of the personnel

Specifies the necessary qualifications and training for personnel operating or maintaining the device, especially in hazardous environments.

5.4 Safety instructions

Provides critical safety instructions to prevent hazards during device operation, transport, installation, and maintenance.

5.5 Responsibilities of the operator

Outlines the duties and responsibilities of the device operator for ensuring safe usage and hazard awareness.

6 Transport and storage

7 Construction and Planning

8 Installation

8.1 Assembly work preparations

Outlines essential preparatory steps and safety precautions before device installation, covering electrical and pressure hazards.

8.2 Installation of the device

Provides detailed instructions for physically installing the ultrasonic gas meter, including piping and connection box.

8.3 Connecting the device electrically

Details the procedures for making all necessary electrical connections to the device, including power and interfaces.

8.4 Installing the pressure connection

Explains how to properly install the pressure connection for the device, with options for shut-off valves.

9 Start Up

9.1 Comparing meter parameters

Guides users on comparing device parameters with calibration or test certificates for accurate operation.

9.2 Checking functions of the USM

Describes how to verify the operational functions of the ultrasonic gas meter after installation, checking flow and pressure.

10 Operation

10.1 Measuring values and parameters

Details how measuring values and parameters are organized in a matrix structure and accessed via display or software.

10.2 Calling up and changing the parameters via the ultrasonic electronics

Provides instructions for navigating and modifying device parameters using the ultrasonic electronics' control panel and buttons.

11 Maintenance

11.1 Maintenance schedule

Outlines the recommended maintenance schedule and associated activities for device longevity and optimal performance.

11.2 Checking the device for leaks

Describes the procedure and frequency for checking the device for leaks, including recalibration checks.

12 Alarm and warning messages

12.1 Alarm messages

Lists and explains all possible alarm messages generated by the device, indicating operational status and faults.

12.2 Warning messages

Lists and explains all possible warning messages generated by the device, indicating potential issues or deviations.

12.4 Troubleshooting

Offers guidance on how to resolve common issues and problems encountered with the device, suggesting contact with service.

13 Technical specifications

13.1 Performance data

Details the performance characteristics and specifications of the device, including power, interfaces, and environmental conditions.

14 USM GT400 Approval

14.1 Metrological approvals

Lists the metrological approvals obtained by the device, such as MID and MC type approvals.

14.2 Pressure devices approval

Details the approvals related to pressure device standards and regulations like PED and ASME.

14.4 Explosion protection approval

Lists the explosion protection approvals, including ATEX, IECEx, and CSA standards for hazardous environments.