120 Rockwell Automation Publication 2094-UM001D-EN-P - May 2010
Chapter 5 Connecting the Kinetix 6000 Drive System
External Shunt Module
Connections
Follow these guidelines when wiring your external active or passive shunt
module.
Figure 67 - Shunt Module Wiring
Figure 68 - Shunt Module Jumper Settings
(1) These are the default jumper settings.
IMPORTANT
When tightening screws to secure the wires, refer to the tables
beginning on page 91
for torque values.
IMPORTANT
To improve system performance, run wires and cables in the wireways as
established in Chapter
2.
Use This
Shunt Module
Cat. No.
With This
Drive Module
Do This
Power rail mounted
shunt module.
2094-BSP2 N/A
Verify the internal shunt jumper is in place between RC-2 and RC-3, as
shown in the figure below.
Verify the thermal switch jumper is in place between TS-1 and TS-2, as
shown in the figure below.
External passive shunt
module connected to
the power rail shunt
module.
1394-SRxxxx
2094-BSP2
Shunt module
Remove the internal shunt jumper between RC-2 and RC-3.
Remove the thermal switch jumper between TS-1 and TS-2
(if your shunt module includes a thermal switch).
Refer to External Shunt Modules on page 44
for noise zone considerations.
Refer to Shunt Module Wiring Examples on page 209
.
Refer to the installation instructions provided with your Bulletin 1394 shunt
module, publication 2090-IN004
.
External active shunt
module connected to
the DC bus.
1336-Wxxxx (requires
external resistor)
2094-xCxx-Mxx
IAM module
Refer to External Shunt Modules on page 44 for noise zone considerations.
Refer to Shunt Module Wiring Examples on page 209
.
Refer to the installation instructions provided with your Bulletin 1336
chopper module, publication 1336-5.65
.
1 2 3
1 2
1 2 3
1 2
COL
INT
DC+
TS2
TS1
COL
INT
DC+
TS2
TS1
External Shunt Resistor
(RC) Connector
Kinetix 6000 Shunt Module, Top View
(catalog number 2094-BSP2)
External Thermal Switch
(TS) Connector
Cable Shield
Clamp
Jumpers
(1)

Table of Contents