Rockwell Automation Publication 2094-UM001D-EN-P - May 2010 193
Specifications and Dimensions Appendix A
Environmental Specifications
AC Line Filter
Specifications
The tables below contain specifications for AC line filters available for
Kinetix 6000 servo drive systems.
Table 111 - AC Line Filter Specifications
Table 112 - AC Line Filter Selection
Specification Operational Range Storage Range (nonoperating)
Ambient temperature 0…50 °C (32…122 °F) -40…70 °C (-40…158 °F)
Relative humidity 5…95% noncondensing 5…95% noncondensing
Altitude 1000 m (3281 ft) 3000 m (9843 ft) during transport
Vibration
5…55 Hz @ 0.35 mm (0.014 in.) double amplitude, continuous displacement; 55…500 Hz @
2.0 g peak constant acceleration
Shock 15 g, 11 ms half-sine pulse (3 pulses in each direction of 3 mutually perpendicular directions)
AC Line Filter
Cat. No.
Voltage Phase Current
Power
Loss
W
Leakage
Current
mA
Weight
kg (lb)
Humidity Vibration
Operating
Temperature
2090-XXLF-X330B
500V AC
50/60 Hz
Three
30 A @ 50 °C
(122 °F)
38 64
2.7
(5.9)
90% RH
10…200
Hz @ 1.8 g
-25…85 °C
(-13…185 °F)
2090-XXLF-375
75 A @ 50 °C
(122 °F)
57
50
5.2
(11.4)
2090-XXLF-375B 108
2090-XXLF-3100
100 A @ 50 °C
(122 °F)
75 73
9.5
(20.9)
IAM Module
Cat. No.
AC Line Filter
Cat. No.
2094-AC05-MP5-x
2090-XXLF-X330B2094-AC05-M01-x
2094-AC09-M02-x
2094-AC16-M03-x 2090-XXLF-375
2094-AC32-M05-x 2090-XXLF-3100
2094-BC01-MP5-x
2090-XXLF-X330B2094-BC01-M01-x
2094-BC02-M02-x
2094-BC04-M03-x 2090-XXLF-375B
2094-BC07-M05-x 2090-XXLF-3100

Table of Contents