258 Rockwell Automation Publication 2094-UM001D-EN-P - May 2010
Appendix E Changing the Default IDN Parameter Values
In this example, the new tag creates a source value (that you entered) that
the MSG instruction uses to overwrite the existing P-0-099 IDN value.
6. Click the Communication tab.
The Communication tab opens.
7. Click Browse.
8. Select your Bulletin 2094 module.
9. Click OK.
The MSG instruction writes the new IDN value to your drive.
10. Click OK to close the Message Configuration dialog box.
TIP
To verify your SERCOS IDN Write instruction was successful, you
can perform another SERCOS IDN Read instruction for the IDN in
question.