Rockwell Automation Publication 440G-UM001B-EN-P - May 2016 39
Description of Operation Chapter 4
1. Undo locking screw.
2. Lift locking arm using a screwdriver and actuate the guard door handle.
Figure 3 - Auxiliary/Manual Release
IMPORTANT The mechanical release is not a safety function.
The machine manufacturer must select and use a suitable release according
to the risk assessment.
The correct function must be checked at regular intervals.
ATTENTION: The locking screw must be screwed back in and sealed after
assembly and after use of the manual release (for example, with sealing
lacquer). Tightening torque is 0.5 Nm.