78 Rockwell Automation Publication D2-3518-4 - January 2020
Chapter 9 Parameter Descriptions
Figure 34 - Rectifier Status (34) Frame 3
Frame 4 drives (firmware version 2.x) only:
Figure 35 - Rectifier Status (34) Frame 4
Displays a fault from the rectifier. The rectifier writes a fault code into this
parameter through a data link.
Set to match the type of motor connected: Induction, Synchronous Reluctance,
or Synchronous Permanent Magnet.
35
Rctfr Fault
Range: 0...299
Default: Read Only
Access: 1 Path: Monitor > Application
See also:
40
Motor Type
Range: 0 = Induction
1 = Synchr Reluc
2 = Synchr PM
Default: 0 = Induction
Access: 1 Path: Motor Control > Motor Data
See also:
xxxx
0011234567891112131415
x =Reserved
Bit #
OK to Run Inverter
Rectifier Running
Rectifier Faulted
Rectifier in Limit
Rectifier Synchronized
Rectifier Phased ACB
Rectifier at Voltage
Rectifier Regenerating
Fault Reset Echo
Nibble 1Nibble 2Nibble 3Nibble 4
Rectifier Carrier Sync
Bit 0 Indicates OK to Run
Standby
x
0011234567891112131415
x =Reserved
Bit #
OK to Run Inverter
Rectifier Running
Rectifier Faulted
Rectifier in Limit
Rectifier Synchronized
Rectifier Phased ACB
Rectifier at Voltage
Rectifier Regenerating
Fault Reset Echo
Nibble 1Nibble 2Nibble 3Nibble 4
Rectifier Carrier Sync
Loop Control Enable
Appl. Digital Out 3
Bit 0 indicates OK to run
Appl. Digital Out 4
Standby