Setting photocell mode during gate opening (FT2)

DISABLED. Photocell is not active or not installed.

STOP. The gate stops and remains stationary until the next command is received.

IMMEDIATE REVERSE. The gate reverses immediately if the photocell is activated during gate opening.

TEMPORARY STOP. The gate stops as long as the photocell is obstructed. The gate resumed opening when the photocell
is cleared.

DELAYED REVERSE. The gate stops if the photocell is obstructed. The gate closes when the photocell is cleared.

Setting photocell mode during gate closing (FT2)

DISABLED. Photocell is not active or not installed.

STOP. The gate stops and remains stationary until the next command is received.

IMMEDIATE REVERSE. The gate reverses immediately if the photocell is activated during gate closure.

TEMPORARY STOP. The gate stops as long as the photocell is obstructed. The gate resumed closing when the photocell
is cleared.

DELAYED REVERSE. The gate stops if the photocell is obstructed. The gate opens when the photocell is cleared.

Photocell (FT2) mode with gate closed
This parameter is not visible if $ , $  or $  is set.

If the photocell is obstructed, the gate cannot open.

The gate opens when an open command is received, even if the photocell is obstructed.

The photocell sends the gate open command when obstructed.

Enable close command 6 s after activation of photocell (FT1-FT2)
N.B.: This parameter is not visible if
$
or
$
is set. NOTE: in the case of photocells being blanked during
opening, the 6 secs. count starts when the wings are completely open.

Disabled.

Enabled. When the photocell barrier FT1 is crossed, a close command is sent 6 seconds later.

Enabled. When the photocell barrier FT2 is crossed, a close command is sent 6 seconds later.
 
Setting motor stop distance

01= faster deceleration/shorter stop distance ... 05= slower deceleration/longer stop distance.

Selecting installation position of motor relative to gate (seen from interior side)
NB: YMJUTXNYNTSIFYFWJVZJXYRJXXFLJIFYFFUUJFWXTSYMJINXUQF^\MJSJ[JWYMNXUFWFRJYJWNXRTINܪJI5WJXXYMJ
PROG key until $33 appears on the display, then repeat the acquisition procedure (see chapter 11.2).
N.B.: in the event of a reset to restore the default parameters, this parameter must be set again manually.

Motor installed on left.

Motor installed on right.

(TSܪLZWNSLXJSXNSLJILJ COS1

Sensing edge NOT INSTALLED.

NC contact (normally closed). The gate reverses only when opening.

Contact with 8k2 resistor. The gate reverses only when opening.

NC contact (normally closed). The gate always reverses.

Contact with 8k2 resistor. The gate always reverses.

(TSܪLZWNSLXJSXNSLJILJ COS2

Sensing edge NOT INSTALLED.

NC contact (normally closed). The gate reverses only when closing.

Contact with 8k2 resistor. The gate reverses only when closing.

NC contact (normally closed). The gate always reverses.

Contact with 8k2 resistor. The gate always reverses.