Setting safeguarded closure/opening activation time
N.B.: this parameter is not visible if the value of parameter  = .

Wait time settable from 2 to 90 s.

Wait time settable from 2 to 9 min.

Selection of the battery operation management
Setting a value different than  a battery voltage level check is activated. The desired operation type can be selected
via parameter  and an error alert can be activated through the COR output via parameter .

The control unit always accepts commands until the battery is completely exhausted.

The command becomes active when the battery voltage drops to the minimum threshold (22Vdc for battery 2x12Vdc)

The command becomes active when the battery voltage drops to the medium threshold (23Vdc for battery 2x12Vdc)

The command becomes active when the battery voltage drops to the maximum threshold (24Vdc for battery 2x12Vdc)

Selecting the battery operation limitations
N.B.: the parameter is visible only if par.  is different than 

There is no limitation for the commands when the battery voltage drops under the selected threshold. An error alert may
be activated via the COR output (if parameters  and  are adequately set).

When the battery voltage drops under the threshold selected with par. , the control unit accepts only opening
commands and does not perform closing.

When the battery voltage drops under the threshold selected with par. , after a 5 s pre-flashing, the control unit
automatically opens the barrier's boom and accepts only a closing command.

It accepts only closing commands even if the ORO input is active and if the parameter is  .

Selection of the battery type and consumption reduction
NOTE: An INCORRECT setting of this parameter, when there is no mains voltage, blocks the functions and the display
shows the message EW/2 (if set to  or  and the battery is 2x12Vdc) or an error alert E RG.

Battery 24Vdc (2x12V). Acceleration/deceleration/speed reduction enabled, to increase the battery life.

Battery 36Vdc (3x12V). Acceleration/deceleration/speed reduction enabled, to increase the battery life.

Battery 36Vdc (3x12V). No performance reduction, maximum battery consumption.
 
Restoring factory default values
NOTE This procedure is only possible is NO data protection password is set.
P1
P2
x4 s
Warning! Restoring default settings cancels all settings made previously except for parameter $,,,: after
restore, check that all parameters are suitable for the installation.
Press and hold the PLUS + and MINUS - button until the unit switches on.
The display flashes after 4 s U(V.
The default factory settings have now been restored.
Note:NYNXUTXXNGQJYTWJXJYYMJUFWFRJYJWXNSFXJHTSI\F^\MJSYMJHTSYWTQZSNYNXX\NYHMJITSGJKTWJYMJܪWR\FWJ
version appears on the display, press and hold down the S (UP ARROW) and T (DOWN ARROW) buttons for 4s.
.IJSYNܪHFYNTSSZRGJW
9MJNIJSYNܪHFYNTSSZRGJWHTSXNXYXTKYMJ[FQZJXTKYMJUFWFRJYJWXKWTRQ to Q.
N.B.: The values shown in the table are indicative only.
Q 
HW version.
Example: 
Q 
Year of manufacture.
Q 
Week of manufacture.
Q 
Serial number.
Q 
Q 
Q 
FW version.