24
the CP parameter has the value “01”.
Parameters temporary unlock rules: ll in the previous
password on the parameters P1, P2, P3, P4 and after go
to the CP parameter and checking his value, it should
be “00”.
It’s possible to delete the password, only if you know it,
in this way: insert the password to unlock the “+” and
n.
par.
VALORI E DESCRIZIONE DEFAULT
A2 Automatic closing after pause time
0 → OFF not automatic closing
1-15 → numers of reclosing chance
99 → it always reclosing
0
A3 Automatic closing after blackout
0 → OFF it does not close when the power comes back
1 → ON it closes when the power comes back
0
A4 STEP BY STEP (PP)
0 → OPEN – STOP – CLOSE – STOP – OPEN - STOP
1 → PP CONDOMINIUM, when it is completely opens, it renews pause time
2 → PP CONDOMINIUM, when it is completely opens, it closes
3 → OPEN – CLOSE – OPEN - CLOSE
4 → OPEN – CLOSE – STOP – OPEN - CLOSE
0
A5 Preashing
0 → ashing light starts to ash when the gate moves
1-60 → SECOND anticipate time of preashing before the gate moves
99 → in opening not enables, 5 seconds preashing in closing
0
A6 PP Condominium Pedestrian
0 → OFF pedestrian makes: OPEN – STOP – CLOSE – STOP – OPEN - STOP
1 → ON pedestrian always open
0
A7 Deadman
0 → OFF normal function
1 ON the gate moves only if You press the button OPEN and CLOSE
0
A8 Open gate led (SC)
0 → when the gate is closed the led is switch off, otherwise the led is xed on
1 → slow ashing in opening, fast in closing and xed when the gate is completely open, triple ashing
when the gate stopped in the middle of the travel (it repeats every 15 sec.)
2 SC output is used to power the photocells and to make the photocells test (see pag. 22)
0
11 Slow-down travel motor 1
1-30 → PERCENTAGE of slow-down travel respect of total travel
15
12 Slow-down travel motor 2
1-30 → PERCENTAGE of slow-down travel respect of total travel
15
13 Tollerance of the position in which leaf 1 is consider closed
1-99 → MILLESIMUM respect of total travel
(this parameter is not shown if there are on the limit switches or timing function)
10
14 Tollerance of the position in which leaf 2 is consider closed
1-99 → MILLESIMUM respect of total travel
(this parameter is not shown if there are on the limit switches or timing function)
10
15 Lenght of pedestrian travel
1-99 → PERCENTAGE of pedestrian opening respect of total travel
99(2 leafs)
50(1 leaf)
16 Recovery margin for timing functioning
0 → 3 sec.
1 6 sec.
0
21 Pause time before automatically reclosing. When one of the photocells is darkened, the timer of
pause time is stopped, when the beam of photocells is restored the timer starts again the counting
of pause time.
0-90 → SECONDS of pause time before of automatically reclosing
92-99 → from 92 the second number shows You the MINUTES of pause time before of automatically
reclosing (from 2 to 9 minutes)
30
“-” button action, after set the null password P1=00,
P2=00, P3=00, P4=00, and remember to conrm it with
parameter “CP”.
If you forget the password please contact the assistance.
TABLE 3 “EXTENDED” MODE PARAMETERS