25
H70/200AC
22 Working time motor 1
0-99 → SECONDS
It shoes the motor 1 working time (It is not showed if there is on the encoder)
20
23 Working time motor 2
0-99 → SECONDS
It shoes the motor 2 working time (It is not showed if there is on the encoder)
20
24 Double working time
0 → OFF
1 → ON
It is not shown if there is on the encoder
0
25 Opening delay (motor 2)
0-60 → SECONDS
3
26 Closing delay (motor 1)
0-60 → SECONDS
5
27 Inversion time after the contact with safety edge or anticrushing
0-99 → inversion SECONDS
2
28 Anticipate time of electric lock respect on the movement
0-2 → SECONDS 1
29 Electric lock duration (activation who follows the anticipate time PAR.28)
0-6 → SECONDS
3
31 Torque level during the normal travel
1-8 → LEVEL (1 = minimum... 8 = maximum)
6
32 Torque level during the slow-down
1-8 → LEVEL (1 = minimum... 8 = maximum)
8
33 Torque level during the start up
0 → OFF start up not enable
1-8 → ON LEVEL (1 = minimum... 8 = maximum)
8
34 Conguration of start up to avoid the tear on starting
0 → OFF soft start not enable
1 → soft start
2 → slow soft start
2
35 Torque level of the start up after an inversion due to safety edge or anticrushing
0 → OFF start up not enable, the gate inverts with the torque settled during the normal travel
1-8 → LEVEL (1 = minimum... 8 = maximum)
8
36 Start up times
1-20 → SECONDS of the start up torque
3
38 Release thrust: when it receives an input and the gate is completely closed, it makes a closing for a time
settled and after it opens. It helps a release of electric lock.
0 → OFF it normally starts and it does not make the inversion. The release thrust is not enable
1-4 → SECONDS time of the rst closing
0
41 Slow-down speed
0 → slow-down not enables
1 → slow speed during the slow-down
2 → very slow speed during the slow-down
1
42 Sensibility to nd an obstacle during the normal travel
1-99 → sensibility (1=not sensible ... 99=max sensibility)
ATTENTION: for 6 poles mot set a value less than 60
20
43 Sensibility to nd an obstacle during the slow-down
1-99 → sensibility (1=not sensible ... 99=max sensibility)
5
49 Automatic reclosing chances after an inversion due to safety edge or anticrushing
0 → NOT automatic reclosing due to safety edge or anticrushing
1-3 → numbers of automatic reclosing chances due to safety edge or anticrushing
0
50 Behaviour if we interrupt the beam of photocell 1 (FT1) during the opening
0 → IGNORE, it does nothing or FT1 is not installed
1 → STOP, the gate stops until the next input
2 → IMMEDIATELY INVERSION, so it makes a closing
3 → TEMPORARY STOP, when the beam is restored it continues to open
4 → INVERTS when the beam is restored the gates inverts, so it makes a closing
0