PRT-LT Series Readers fv1.25 Rev. G 2016-10-08
Page 16 from 17
Technical Specification
Supply voltage Nominal 12VDC, min,/max. range 10-15 VDC
Current consumption
(average)
PRT12LT: 65mA
PRT12LT-BK: 45mA
PRT32LT: 65 mA
PRT42LT: 65 mA
PRT42LT-BK: 45mA
PRT62LT: 45mA
PRT64LT: 65mA
PRT66LT: 45 mA
Reading distance PRT62LT: up to 12 cm, others: up to 15 cm
Note: Reading distance is defined for good quality proximity cards
placed in optimal position against the reader. For all PRT-LT readers
optimal card position is in the front of the reader (card surface
parallel to front of the reader)
Anti-sabotage protection
(Tamper)
NC contact, 50mA/24V, IP67
Proximity cards EM 125KHz (EM4100/4102 compatible)
Communication distance Between ACU and PRT reader: max. 150 m
Between main PRT reader and external PRT reader: max. 150 m
Environmental class
(according to EN 50131-1)
Class IV, outdoor-general, temperature: -25°C- +60°C, relative
humidity: 10 to 95% (non condensing)
Class I, Indoor, temperature: +5°C- +40°C, relative humidity: 10 to
95% (non-condensing)
PRT12LT/PRT12LT-BK: Class IV
PRT32LT: Class I
PRT42LT/PRT42LT-BK: Class I
PRT62LT: Class IV
PRT64LT: Class IV
PRT66LT: Class IV
Dimensions H x W x D PRT12LT/PRT12LT-BK: 150.5 X 46 X 23 mm
PRT32LT: 105 X 105 X 31
PRT42LT/PRT42LT-BK: 151.5 X 45 X 20.5 mm
PRT62LT: 100 X 45 X 25 mm
PRT64LT: 115 X 80 X 35 mm
PRT66LT: 85 X 85 X 27 mm
Weight PRT12LT/PRT12LT-BK: 150g
PRT32LT: 140g
PRT42LT/PRT42LT-BK: 90g
PRT62LT: 100g
PRT64LT: 120g
PRT66LT: 120g
Approvals CE