V L F > H F R E C E I V E R S
f
R & S E K 8 9 5 / R & S E K 8 9 5
User Manual
f
Control and Display Elements
Bargraph
consisting of
25 individual
bars
Description
In the modulation mode field the
currently effective modulation mode (e.g.
CW) is displayed.
Possible displays:
AM FSK> F7B>+
CW AFSK+ F7B++
USB AFSK> FM
LSB F7B>> IUSB
FAX1 F7B+> ILSB
FSK+
For
R&S EK 895 only:
Via the modulation mode menu (see
3.1.8.3) the modulation mode can be
altered.
For
R&S EK 896 only:
With the modulation mode keys (19) and
the modulation mode menu (see 3.1.8.2)
the modulation mode can be altered.
LEVEL INDICATION, e.g. dBoV
see 3.1.18.15 for R&S EK 895 or 3.1.21.8 for
R&S EK 896
Depending on the set type of control (see
control type field (5)) the bargraph in>
dicates either the receive level or the
control voltage.
AGC
The bargraph indicates the current receive
level.
MGC
The bargraph indicates the control volt>
age set by means of the HF control (22).
No.
3
4
Control or display
element
Design
Modulation
mode field
consisting of the
display
MODULATION
and three
14>segment
display elements
MODULATION
0
30
60
90
120
RF
dBoV
0
30
60
90
RF
e.g.
dBoV
e.g.
dS
6164.0717.02_01
> 3.74 >