Altering the Operating Voltage
A1.2 Altering the Operating Voltage
1. Switch VLF>HF receiver off.
Æ LED POWER is dark
(control unit 2 ∫LOCAL∫ (R&S EK!895, = op>
tion 'Control Unit GB 890') or control unit
(R&S EK!896)).
POWER
Æ LED ON is dark
(control unit 1 ∫REMOTE∫ (R&S EK 895)).
EIN
.
ON
2. Disconnect mains cable from plug X67.
3. Open fuse holder.
4. For the desired operating voltage insert
respective fuse into the fuse holder.
100 V = T1.25/250 V
120 V = T1.25/250 V
220 V = T630/250 V
(basic fitting ex works)
240 V = T630/250 V
5. Insert fuse holder in such a way that the
arrow (π) points to the desired operating
voltage.
Basic setting ex works: 220 V
6. After the operating voltage has been
altered, carry out steps 1 and 2 in the
reverse order.