Frequency Scanning
A3.4.7 Hold Time
Command syntax:
Code: HTS
Parameter: ................... a
Possible entries / replies
Range: ......................... 0 to 65534
Stepwidth: ................... 1 ms
Entry: .......................... in ms
Command: HTSf (automatic stop of scanning)
Note:
The hold time is required for frequency scan>
ning (see A3.4).
Due to the command HTS<parameter>, to
the dwell time (see A3.4.6) the hold time is
added, once the receive level exceeds the set
digital threshold (see A3.4.5).
The command HTSf automatically stops scan>
ning, once the receive level exceeds the set
digital threshold (see A3.4.5).
Example 1:
Entering a hold time of 3.5 s.
Command = rAxxHTS3500?
Example 2:
Inquiry of the currently effective hold time
Command = rAxxHTS??
Æ Reply = rAxxDWS3500?
A hold time of 3.5 s is set.
Example 3:
Programming an automatic stop of scanning
Command = HTSf
Æ Operating mode MANUAL
6164.0717.02_01