V L F > H F R E C E I V E R S
f
R & S E K 8 9 5 / R & S E K 8 9 6
User Manual
f
Special Functions
A3.7.14 Inhibiting a Channel
Command syntax:
Code: CL
Parameter: .................... a
Possible entries
Range: .......................... 0 to 999
Command: CLa (clear all)
Example 1:
Inhibiting channel 125 and indicating the chan>
nel contents
Command = rAxxCL125K125,??
Æ Reply =
rAxxK125,eF6000000I5B800W2R1DT2D45?
Note:
The small letter 'e' indicates, that this channel
is inhibited. Channels of this kind are not called
up during CHANNEL SCANNING (see A3.5).
In channel 125 the following settings are
stored:
f Channel status: K125,e = inhibited
f Frequency: F6000000 = 6 MHz
f Modulation mode: I5 = CW
f BFO frequency: B800 = 800 Hz
f Bandwidth: W1 = 150 Hz
f Control type: R1 = AGC+DGC
f Control time: DT2 = 500 ms
f DGC value: D45 = 45 dBoV
EMF
Example 2:
Inhibiting all channels
Command = rAxxCLa?
A3.7.15 Reactivating a Channel
Command syntax:
Code: RS
Parameter: .................... a
Possible entries
Range: .......................... 0 to 999
Example:
Reactivating channel 125 and indicating the
channel contents
Command = rAxxRS125K125,??
Æ Reply =
rAxx K125F6000000I5B800W2R1DT2D45?
In channel 125 the following settings are
stored:
f Frequency: F6000000 = 6 MHz
f Modulation mode: I5 = CW
f BFO frequency: B800 = 800 Hz
f Bandwidth: W1 = 150 Hz
f Control type: R1 = AGC+DGC
f Control time: DT2= 500 ms
f DGC value: D45 = 45 dBoV
EMF
Note:
The channel can now be called up again during
CHANNEL SCANNING (see A3.5).
6164.0717.02_01
> A3.31 >