R&S
®
CMW 500 GPRF Applications
GPRF Command Reference
Operating Manual 1202.3986.32 – 03 177
ROUTe:GPRF:GEN<i>:RFSettings:CONNector <Output Connector>
Selects the output connector for the RF generator signal.
<Output Connector> RF1O: RF 1 OUT
RF1C: RF 1 COM
RF2C: RF 2 COM
Def. value: RF1C
Example See Generating a CW Signal
Characteristics Firmware version V1.00
SOURce:GPRF:GEN<i>:RFSettings:EATTenuation <External Att>
Defines an external attenuation (or gain, if the value is negative), to be applied to the
selected RF output connector (ROUTe:GPRF:GEN<i>:RFSettings:Connector).
<External Att> Range: –50.00 dB to +90.00 dB (increment 0.01 dB)
Def. value: 0.00 dB
Def. unit: dB
Example See Generating a CW Signal
Characteristics Firmware version V1.00
7.4.2.4 Constant-Frequency Settings
The following commands configure the constant-frequency generator mode.
SOURce:GPRF:GEN<i>:RFSettings:FREQuency <Frequency>
Selects the frequency of the RF generator (Generator Frequency). Some of the
baseband modes (modulation types) modify the generator frequency.
<Frequency> Range: 70 MHz to 3300 MHz (increment 0.1 Hz)
Def. value: 1200.000 MHz
Def. unit: Hz
Example See Generating a CW Signal
Characteristics Firmware version V1.00
SOURce:GPRF:GEN<i>:RFSettings:LEVel <LEVel>
Sets the base level (Level (RMS)) of the constant-frequency RF generator.