Operating Manual 1202.3986.32 – 03 264
acquisition mode is active (CONFigure:GSM:MEAS<i>:MEValuation:AMODe
PATTern).
<Pattern 0>,
...,
<Pattern 7>
Pattern selection for corresponding timeslot (0 to 7)
OFF: No signal expected
GMSK: GMSK-modulated normal bursts
EDGE: 8PSK-modulated normal bursts
Def. value: OFF (timeslots 0, 6, 7), EDGE (timeslots 1 to 5)
Example See Selecting Specific Burst Types
Characteristics Firmware version V1.00
8.4.2.7 Power vs. Time Settings
The following commands configure the "Power vs. Time " measurement.
CONFigure:GSM:MEAS<i>:MEValuation:RPMode <Mode>
Defines how the reference power, i.e. the 0-dB line in the measurement diagram, is
calculated.
<Mode> CURRent: Current
AVERage: Average
DCOMpensated: Data Compensated
Def. value: AVERage
Example See Performing Single Shot Measurements
Characteristics Firmware version V1.00
8.4.2.8 Spectrum Modulation Settings
The following commands define settings for spectrum modulation frequency (ACP
modulation) measurements.
CONFigure:GSM:MEAS<i>:MEValuation:SMODulation:FOFFsets
<Status 0> | <Freq Offset 0>, ..., <Status 19> | <Freq Offset 19>
Defines the frequency offsets to be used for ACP modulation measurements. The
offsets are defined relative to the analyzer frequency. Up to 20 offsets can be defined
and enabled.