R&S
®
CMW 500 GSM Applications
GSM Command Reference
Operating Manual 1202.3986.32 – 03 274
Characteristics Firmware version V1.00
8.4.2.12 Limits (Power vs. Time)
The following commands define limit lines for power vs. time measurements.
CONFigure:GSM:MEAS<i>:MEValuation:LIMit:PVTime:ABPower<number>
<Start PCL>, <End PCL>, <Lower Limit>, <Upper Limit>, <Status>
Defines and activates limits for the average burst power, i.e. tolerances for ranges of
template power control levels (TPCLs).
<number> Number of the group
Range: 1 to 10
Def. value: 1
<Start PCL>,
<End PCL>,
Number of first and last TPCL to which the limits are applied
Range: 0 to 31
Def. values: see table below
<Lower Limit>, Range: -10 dB to 0 dB
Def. values: see table below
<Upper Limit>, Range: 0 dB to 10 dB
Def. values: see table below
<Status> ON: Enable limits for the given <number>
OFF: Disable limits for the given <number>
Def. values: see table below
Characteristics Firmware version V1.00
The default settings for GSM 900/1800/1900 are according to the following table. The
default settings for GSM850, GSM GT800, and GSM400 are identical to GSM900:
<Status> <Start
PCL>
<End
PCL>
<Lower Limit> [dB] <Upper Limit> [dB]
<number>=1 ON 31 31 -2 2
<number>=2 ON 0 2/8/8 -2/-3/-3 2/3/3
<number>=3 ON 3/9/9 15/13/13 -3/-4/-4 3/4/4
<number>=4 ON 16/14/14 31/28/29 -5 5
<number>=5 OFF/ON/ON -/29/30 -/29/31 -/-2/-2 -/5/2
<number>=6 OFF/ON/OF
F
-/30/- -/31/- -/-3/- -/2/-
<number>=7 to 10 OFF - - - -