Remote Control
R&S
®
CMW500
158User Manual 1173.9463.02 ─ 06
sub-instrument, not per instrument. That means e.g. that within sub-instrument 1 the
value TX1 refers to another physical TX module than within sub-instrument 2.
The following table lists the supported parameter values and used *RST values for selec-
tion of RF connectors and TX/RX boards.
Sub-Instrument 1 Sub-Instrument 2
Input connector
RF1C | RFAC RF2C | RFAC
Output connector
RF1C | RF1O | RFAC |
RFAO
RF2C | RFAC
Mapping RFAC, RFAO
RF1C, RF1O RF2C, n/a
TX module
TX1 TX1
RX module
RX1 RX1
*RST connectors
RF1C RF2C
*RST TX/RX
TX1, RX1 TX1, RX1
5.4.5.9 Four RF Paths, Two Frontends, One Sub-Instrument
This section applies to an instrument with four RF paths, two advanced frontends and up
to four instances per firmware application. All resources are grouped in one sub-instru-
ment.
All firmware application instances can access both frontends. The following table lists the
supported parameter values and used *RST values for selection of RF connectors and
TX/RX boards.
Instance 1 Instance 2 Instance 3 Instance 4
Input connector
RF1C | RF2C | RF3C | RF4C | RFAC | RFBC
Output connector
RF1C | RF1O | RF2C | RF3C | RF3O | RF4C | RFAC | RFAO
| RFBC
Mapping RFAC, RFAO, RFBC
RF1C, RF1O, RF2C
TX module TX1, TX3 (for RF1/RF2 connectors only)
TX2, TX4 (for RF3/RF4 connectors only)
RX module RX1, RX3 (for RF1/RF2 connectors only)
RX2, RX4 (for RF3/RF4 connectors only)
*RST connectors
RF1C RF3C RF2C RF4C
*RST TX/RX
TX1, RX1 TX2, RX2 TX3, RX3 TX4, RX4
5.4.5.10 Four RF Paths, Two Frontends, Two Sub-Instruments
This section applies to an instrument with four RF paths, two advanced frontends and up
to four instances per firmware application. The instrument is split into two sub-instru-
ments.
Control of the Instrument