V L F > H F R E C E I V E R S
f
E K 8 9 5 / E K 8 9 6
Operator Manual
f
List of Commands
6075.6991.82.01
> 2.9 >
Code Function (entry in) Entry
Output
(requested with ?)
Remark
FIB1
24= 2400 Hz
27= 2700 Hz
31= 3100 Hz
40= 4000 Hz
48= 4800 Hz
60= 6000 Hz
80= 8000 Hz
see A3.8.3
1)
I Modulation mode 15 to 18 15= L USB
16= L LSB
17= L ISB USB
18= L ISB LSB
see 2.3.2
IDENT Software
type
Ident. No.
e.g.
ek896,
6038297302
see A3.8.12
1)
IF IF signal
Parameter a
Type of frequency
Parameter b
Control type
Parameter c
Frequency (Hz)
0 to 2,
0 to 1,
0 to 40000
0= no signal
1= signal with
variable fre>
quency
2= signal with
fixed fre>
quency
(option)
0= off
1= on
0 to 40000
see A3.8.10
1)
K Edit channel contents
Inquire current receiver
setting
0 to 999 0 to 999
≤≥
= MANUAL
0 to 999=
CHANNEL
0,e to 999,e=
channel inhibited
see A3.7.9
1)
see 2.4.2
Ks, Call up a channel 0 to 999 see 2.4.1
L Inquire receive level (dBoV) 0 to 120 see A3.7.6
1)
M Inquire operating status 0= MANUAL
2= CHANNEL
see A3.8.6
1)
OP Inquire options 0= none
1= Control Unit
GB 890
see 2.5.1
1)
These commands are described in the User Manual 6045.6712.12.xx.