Frequency
1.1.7.4 Entering the Tuning Knob
Stepwidth
Upon actuation of softkeys MORE and SPEC
(EK!895) or of key MORE (EK 896) as well as
softkeys KNOB and STEP the following display
appears:
VAR STEP xxxx _KHZ ENT
(xxxx= last stored stepdwidth)
The flashing cursor (_) indicates that an entry is
being expected. Enter new stepdwidth via the
numeric keypad.
Range of entry: . . . . . . . 1 Hz to 1000 kHz
Resolution: . . . . . . . . . . 1 Hz
The programmed stepwidth for the tuning
knob takes effect as soon as, in the FRE>
QUENCY mode, the cursor is shifted to the
right>hand side and out of the frequency field
by using the cursor control keys.
1.1.7.5 Enabling the Tuning Knob
Actuate softkeys MORE and SPEC (EK!895) or
key MORE (EK 896) as well as softkeys KNOB
and ON. In the display now ON is underlined.
1.1.7.6 Disabling the Tuning Knob
Actuate softkeys MORE and SPEC (EK!895) or
key MORE (EK 896) as well as softkeys KNOB
and OFF. In the display now OFF is underlined.