EasyManua.ls Logo

Rohde & Schwarz EMI Test ReceiverESCI - Selection of Detectors for Final Measurement

Rohde & Schwarz EMI Test ReceiverESCI
495 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MEAS Key - Receiver R&S ESCI
1166.6004.12 4.38 E-2
Selection of Detectors for Final Measurement
The selection of detectors for the final measurement is made in the right side menu TRACE DETECTOR
(see section "Selection and setting of traces ").
The detectors to be used for the final measurement can be set here for each trace, i.e. any combination
of prescan and final measurement is possible. The required flexibility is thus obtained for the diverse
test specifications which are covered by means of the R&S ESCI.
In the THRESHOLD SCAN mode, with the NB/BB DISCR function active, the receiver automatically
selects the detector to be used in the final measurement on the basis of the results obtained in the
prescan.
Fig. 4-2 Results of prescan and final measurement