MKR-> - Receiver R&S ESCI
1166.6004.12 4.60 E-2
SEARCH
LIMIT OFF
The SEARCH LIMIT OFF softkey disables all limits of the
search range.
IEC/IEEE-bus command: CALC:MARK:X:SLIM OFF
CALC:THR OFF
PEAK
EXCURSION
The PEAK EXCURSION softkey activates an entry box for selecting the
minimum amount by which a signal level must decrease/increase before it is
recognized by the NEXT PEAK and NEXT MIN search functions as a
maximum or minimum.
Input values from 0 to 80 dB are allowed, the resolution being 0.1 dB.
IEC/IEEE-bus command: CALC:MARK:PEXC 10dB
For detailed explanation see softkey PEAK EXCURSION in ANALYZER