R&S FSH Operating the R&S FSH
Saving Events
Operating Manual 1173.6275.12 - 30 22
● Time interval
Saves measurement data every <x> seconds.
You can define the duration of the time interval via the "Time Interval" menu item.
Single sweeps and sweep time
Note that it is not possible to save measurement data every <x> seconds in single
sweep mode, because the R&S FSH only performs one sweep and then stops.
Note also that the time interval must be longer than the sweep time. If the time interval
would be shorter, the R&S FSH would not be able to save data, because a sweep has
to be complete before the R&S FSH is able to save the data.
● Limit failure
Saves measurement data if a limit line is violated. (not supported by Geotagging
mode yet)
The R&S FSH provides different modes for handling limit check failures. You can
select one via the "Limits Save Mode"
- Start on failure: starts to save measurement data if a limit line is violated.
- Stop on failure: stops to save measurement data if a limit line is violated.
- Save only failure: saves only the sweeps that actually fail a limit check.
● Distance interval
Saves measurement data after you have covered a certain distance.
You can define the distance that must covered before data is saved via the
"Distance Interval" menu item.
● Every sweep
Saves the data of all measurement sweeps that are performed.
Storage device
To use the "Save on Event" functionality, you need an SD card or USB stick to store
the data on. The internal memory would probably not be sufficient.
► Press the SETUP key.
► Press the "User Preference" softkey.
► Select the "Recording Storage" menu item.
► From the dropdown menu, select the storage device you prefer (SD card or USB
device)