Operating the Instrument
R&S
®
FSW
96Getting Started 1338.4102.02 ─ 08
Icon Description
Selection mode: the cursor can be used to select (and move) markers in a zoomed
display
(This function is only available and required for older instruments that do not support
multi-touch gestures.)
Measurement zoom: applies to the next display you select;
Displays a dotted rectangle in the diagram that can be expanded to define the zoom
area; the selected diagram is replaced by a new diagram with adapted measurement
settings which displays the selected extract of the trace.
Also provides a context menu to determine the firmware behavior for touch gestures:
●
"Level Lock"
(Default:) The reference level (and thus the attenuation) remains unchanged dur-
ing touch gestures on the screen.
●
"X-Lock"
The x-axis of the diagram is not changed during subsequent touch gestures.
●
"Y-Lock"
The y-axis of the diagram is not changed during subsequent touch gestures.
●
"Adapt Measurement to Zoom (selected diagram)"
Automatically adapts the measurement settings to the currently zoomed display
(Graphical) Zoom mode: applies to the next display you select;
Displays a dotted rectangle in the diagram that can be expanded to define the zoom
area; the selected diagram is replaced by a new diagram which displays an enlarged
extract of the trace.
This function changes the behavior of finger gestures such as dragging or stretching
a finger (see also "Touch gestures in diagrams change measurement settings"
on page 106)
Multiple (graphical) zoom mode: applies to the next display you select;
Allows you to enlarge several different areas of the trace simultaneously.
Displays a dotted rectangle in the diagram that can be expanded to define the zoom
area; a subwindow is added to display an enlarged extract of the trace
This function changes the behavior of finger gestures such as dragging or stretching
a finger (see also "Touch gestures in diagrams change measurement settings"
on page 106)
Zoom off: displays the diagram in its original size
This function only restores graphically zoomed displays. Measurement zooms, for
which measurement settings were adapted, remain untouched.
Data shift: Shifts the data to be evaluated in the result display and re-evaluates the
new data.
Currently, this function is only available in the Transient Analysis application.
Data zoom: Decreases the amount of data to be evaluated in the result display and
re-evaluates the new data, thus enlarging the display of the remaining data.
Currently, this function is only available in the Transient Analysis application.
Accessing the Functionality