Protocol analysisMXO 4 Series
413User Manual 1335.5337.02 ā 07
Remote command:
ā
SBUS<sb>:FORMat on page 704
Export of decode results
1. In the protocol "Shortcuts" tab, press "Export results".
The "Export results" dialog opens.
For details, see Chapter 13.1.7, "Export protocol results", on page 318.
2. Select the details that you want to export and the file format.
3. Tap "Save as".
4. Key in a name and select the file format.
Remote commands
Remote commands to retrieve decode results are described in Chapter 17.16.7, "SPMI
(option R&S MXO4-K550)", on page 812.
13.7.4 Performing SPMI decoding
This chapter explains step by step how to configure and decode the SPMI bus.
13.7.4.1 Configuring SPMI signals
For configuration, assign the lines to the input channels, and define the active states
and the logical thresholds.
For details on configuration settings, see Chapter 13.7.1, "SPMI configuration",
on page 406.
1. Tap the "Bus" activator in the bottom right of the screen.
2. Select the tab of the bus that you want to set up, for example "SB1".
3. Tap the "Protocol type" button. Select the protocol: "SPMI".
4. Tap on "State" to enable the decoding.
An SPMI shortcut appears at the bottom left of the screen. Tap on the shortcut for a
quick access to the "SPMI" dialog settings.
SPMI (option R&S