EasyManua.ls Logo

Rohde & Schwarz MXO 4 Series - Page 513

Rohde & Schwarz MXO 4 Series
925 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Remote control commandsMXO 4 Series
513User Manual 1335.5337.02 ─ 07
B700 | B500 | B350 | B200 | B100 | B50 | B20
Sets a bandwidth limit lower than the maximum. The number
indicates the bandwidth limit in MHz.
B1G5 | B1G
Sets the bandwidth limit to 1500 MHz or 1000 MHz if these val-
ues are lower than the maximum.
*RST: FULL
Usage: Asynchronous command
Manual operation: See "Bandwidth" on page 123
CHANnel<ch>:EATScale
<ExtAttScl>
Sets the attenuation scale for an external divider: linear or logarithmic.
Suffix:
<ch>
.
1 to 4, index of the analog channel
Parameters:
<ExtAttScl> LIN | LOG
*RST: LIN
Usage: Asynchronous command
Manual operation: See "External Attenuation: Scale, Attenuation" on page 124
CHANnel<ch>:EATTenuation <ExtAtt>
Consider a voltage divider that is part of the DUT before the measuring point. The
external attenuation is included in the measurement, and the instrument shows the
results that would be measured before the divider. External attenuation can be used
with all probes.
Suffix:
<ch>
.
1 to 4, index of the analog channel
Parameters:
<ExtAtt> Values depend on the selected scale (CHANnel<ch>:
EATScale on page 513) and the unit of the waveform. See
"External Attenuation: Scale, Attenuation" on page 124. Limits
below are for linear scale.
Range: 0.005 to 1000000
Increment: 0.01
*RST: 1
Usage: Asynchronous command
Manual operation: See "External Attenuation: Scale, Attenuation" on page 124
Acquisition and setup

Table of Contents

Related product manuals