Remote control commandsMXO 4 Series
521User Manual 1335.5337.02 ─ 07
ACQuire:SEGMented:MAX <MaxAcqs>
If ON, the instrument acquires the maximum number of segments that can be stored in
the memory. The maximum number depends on the current sample rate and record
length settings.
If OFF, define the number of segments in a fast segmentation cycle with ACQuire:
COUNt.
Parameters:
<MaxAcqs> ON | OFF
*RST: OFF
Usage: Asynchronous command
Manual operation: See "Acquire maximum" on page 116
17.8.8
Probes
● Common probe settings........................................................................................521
● Settings for active voltage probes.........................................................................525
● Settings for modular probes..................................................................................531
● Settings for current probes....................................................................................535
● Probe attributes.....................................................................................................536
17.8.8.1 Common probe settings
The probe suffix <ch> selects the input channel to which the probe is connected.
PROBe<ch>:SETup:ATTenuation[:AUTO]?....................................................................... 521
PROBe<ch>:SETup:ATTenuation:MANual........................................................................ 522
PROBe<ch>:SETup:ATTenuation:DEFProbe.....................................................................522
PROBe<ch>:SETup:ATTenuation:UNIT............................................................................ 523
PROBe<ch>:SETup:BANDwidth?.................................................................................... 523
PROBe<ch>:SETup:OFFSet:TOMean..............................................................................523
PROBe<ch>:SETup:OFFSet:AZERo................................................................................524
PROBe<ch>:SETup:OFFSet:USEautozero....................................................................... 524
PROBe<ch>:SETup:NAME?........................................................................................... 524
PROBe<ch>:SETup:STATe?........................................................................................... 524
PROBe<ch>:SETup:TYPE?............................................................................................ 525
PROBe<ch>:SETup:ATTenuation[:AUTO]?
Returns the attenuation of a detected or predefined probe.
Suffix:
<ch>
.
1 to 4, index of the analog channel
Acquisition and setup