Remote control commandsMXO 4 Series
542User Manual 1335.5337.02 ─ 07
TRIGger:EVENt<ev>:SOURce <SourceDetailed>
Selects the source of the trigger signal for the selected trigger event. The trigger
source works even if it is not displayed in a diagram.
Available sources depend on the trigger sequence setting. If you trigger on a single
event, all inputs can be used as trigger source. If you trigger on a sequence, only ana-
log channels can be set as trigger source.
Suffix:
<ev>
.
1 = A-trigger, 2 = B-trigger, 3 = reset event
Parameters:
<SourceDetailed> C1 | C2 | C3 | C4 | EXTernanalog | LINE | D0 | D1 | D2 | D3 | D4
| D5 | D6 | D7 | D8 | D9 | D10 | D11 | D12 | D13 | D14 | D15 |
SBUS1 | SBUS2 | SBUS3 | SBUS4
C1 | C2 | C3 | C4
Available for single event and all events in a trigger sequence
EXTernanalog | LINE | D0 | D1 | D2 | D3 | D4 | D5 | D6 | D7 |
D8 | D9 | D10 | D11 | D12 | D13 | D14 | D15 | SBUS1 | SBUS2 |
SBUS3 | SBUS4
Available for single event (EVENt1)
*RST: C1
Usage: Asynchronous command
Manual operation: See "[Source]" on page 40
17.9.2 Trigger sequence
TRIGger:MEVents:AEVents.............................................................................................542
TRIGger:MEVents:SEQuence<se>:COUNt.......................................................................543
TRIGger:MEVents:SEQuence<se>:DELay........................................................................543
TRIGger:MEVents:SEQuence<se>:RESet:EVENt............................................................. 543
TRIGger:MEVents:SEQuence<se>:RESet:TIMeout:TIME...................................................544
TRIGger:MEVents:SEQuence<se>:RESet:TIMeout[:ENABle]............................................. 544
TRIGger:MEVents:AEVents <Type>
Selects the type of the trigger sequence.
Parameters:
<Type> AONLy | ABR
ABR = sequence A B R
*RST: AONLy
Usage: Asynchronous command
Manual operation: See "Trigger sequence" on page 145