Parameters:
<RelativeStart> Range: 0 to 100
Increment: 0.1
*RST: 0
Default unit: %
Usage: Asynchronous command
Manual operation: See "Start Stop" on page 179
LAYout<ly>:ZOOM<zo>:VERTical:RELative:STOP <RelativeStop>
Defines the upper limit of the zoom area on the x-axis, in relative values.
Suffix:
<ly>
.
1...4, index of the SmartGrid layout
<zo> 1...4, index of the zoom
Parameters:
<RelativeStop> Range: 0 to 100
Increment: 0.1
*RST: 100
Default unit: %
Usage: Asynchronous command
Manual operation: See "Start Stop" on page 179
LAYout<ly>:ZOOM<zo>:VERTical:RELative:WIDTh <RelativeSpan>
LAYout<ly>:ZOOM<zo>:VERTical:RELative:SPAN <RelativeSpan>
Defines the height of the zoom area in relative values.
Suffix:
<ly>
.
1...4, index of the SmartGrid layout
<zo> 1...4, index of the zoom
Parameters:
<RelativeSpan> Range: 1E-15 to 100
Increment: 0.1
*RST: 100
Default unit: %
Usage: Asynchronous command
Manual operation: See "Position range" on page 179
LAYout<ly>:ZOOM<zo>:SSCReen