Remote control commandsMXO 4 Series
650User Manual 1335.5337.02 ─ 07
Manual operation: See "Window type" on page 249
CALCulate:SPECtrum<sp>:MAGNitude:LEVel <VerticalMax>
Sets the maximum displayed value on the vertical scale.
Suffix:
<sp>
.
1
Parameters:
<VerticalMax> Range: -1E+26 to 1000000000000000
Increment: 1
*RST: 10
Usage: Asynchronous command
Manual operation: See "Vertical maximum" on page 251
CALCulate:SPECtrum<sp>:MAGNitude:RANGe
<VerticalRange>
Sets the range of the spectrum values to be displayed.
Suffix:
<sp>
.
1
Parameters:
<VerticalRange> Range: 0 to 1000000000000000
Increment: 0.01
*RST: 100
Usage: Asynchronous command
Manual operation: See "Vertical range" on page 251
CALCulate:SPECtrum<sp>:MAGNitude:SCALe <Unit>
Sets the unit for the y-axis.
Suffix:
<sp>
.
1
Parameters:
<Unit> LINear | DB | DBM | DBV | DBUV | DBS | DBHZ
*RST: DBM
Usage: Asynchronous command
Manual operation: See "Magnitude unit" on page 250
CALCulate:SPECtrum<sp>:PRESet
Presets the spectrum measurement.
Spectrum analysis