Remote control commandsMXO 4 Series
693User Manual 1335.5337.02 ─ 07
Suffix:
<m>
.
1...3, index of the power analysis measurement
Return values:
<Actual> Range: -1E+26 to 1E+26
Increment: 1E-10
*RST: 0
Usage: Query only
Asynchronous command
17.15.2.4 Reference level
POWer<m>:HARMonics:REFLevel<rl>:ABSolute:HYSTeresis............................................ 693
POWer<m>:QUALity:REFLevel<rl>:ABSolute:HYSTeresis................................................. 693
POWer<m>:HARMonics:REFLevel<rl>:ABSolute:LLEVel...................................................694
POWer<m>:QUALity:REFLevel<rl>:ABSolute:LLEVel........................................................ 694
POWer<m>:HARMonics:REFLevel<rl>:ABSolute:MLEVel.................................................. 694
POWer<m>:QUALity:REFLevel<rl>:ABSolute:MLEVel....................................................... 694
POWer<m>:HARMonics:REFLevel<rl>:ABSolute:ULEVel.................................................. 694
POWer<m>:QUALity:REFLevel<rl>:ABSolute:ULEVel....................................................... 694
POWer<m>:HARMonics:REFLevel<rl>:LMODe................................................................ 695
POWer<m>:QUALity:REFLevel<rl>:LMODe..................................................................... 695
POWer<m>:HARMonics:REFLevel<rl>:RELative:HYSTeresis.............................................695
POWer<m>:QUALity:REFLevel<rl>:RELative:HYSTeresis..................................................695
POWer<m>:HARMonics:REFLevel<rl>:RELative:LOWer................................................... 695
POWer<m>:QUALity:REFLevel<rl>:RELative:LOWer........................................................ 695
POWer<m>:HARMonics:REFLevel<rl>:RELative:MIDDle...................................................696
POWer<m>:QUALity:REFLevel<rl>:RELative:MIDDle........................................................696
POWer<m>:HARMonics:REFLevel<rl>:RELative:MODE....................................................696
POWer<m>:QUALity:REFLevel<rl>:RELative:MODE.........................................................696
POWer<m>:HARMonics:REFLevel<rl>:RELative:UPPer....................................................697
POWer<m>:QUALity:REFLevel<rl>:RELative:UPPer......................................................... 697
POWer<m>:HARMonics:REFLevel<rl>:ABSolute:HYSTeresis <HystAbs>
POWer<m>:QUALity:REFLevel<rl>:ABSolute:HYSTeresis <HystAbs>
Defines a hysteresis for the middle reference level. A rise or fall from the middle refer-
ence value that does not exceed the hysteresis is rejected as noise.
Suffix:
<m>
.
1...3, index of the power analysis measurement
<rl> 1...4, index of the reference level set
Parameters:
<HystAbs> Range: 0 to 1E+26
Increment: 0.001
*RST: 0.005
Default unit: V
Usage: Asynchronous command