Remote control commandsMXO 4 Series
703User Manual 1335.5337.02 ─ 07
Return values:
<Results_DCRMS> Range: -1E+26 to 1E+26
Increment: 0.1
*RST: 0
Default unit: V
Usage: Query only
Asynchronous command
Manual operation: See "Measurements" on page 291
17.16
Protocols
Configuration settings for all serial protocols........................................................ 703
SPI (option R&S MXO4-K510)..............................................................................707
I²C (option R&S MXO4-K510)...............................................................................725
UART / RS-232 (option R&S MXO4-K510)...........................................................746
CAN (option R&S MXO4-K520)............................................................................ 762
LIN (option R&S MXO4-K520).............................................................................. 795
SPMI (option R&S MXO4-K550)...........................................................................812
10BASE-T1S (option R&S MXO4-K560).............................................................. 827
17.16.1 Configuration settings for all serial protocols
17.16.1.1 General settings
SBUS<sb>[:STATe]........................................................................................................ 703
SBUS<sb>:TYPE...........................................................................................................704
SBUS<sb>:RESult......................................................................................................... 704
SBUS<sb>:FORMat....................................................................................................... 704
SBUS<m>:ZCOupling.....................................................................................................704
SBUS<m>:THReshold....................................................................................................705
SBUS<m>:SETReflevels................................................................................................ 705
SBUS<sb>[:STATe] <ProtocolState>
Enables the decoding of the specified bus.
Suffix:
<sb>
.
1...4, index of the serial bus
Parameters:
<ProtocolState> ON | OFF
Usage: Asynchronous command