Remote control commandsMXO 4 Series
726User Manual 1335.5337.02 ─ 07
17.16.3.1 Configuration
SBUS<sb>:I2C:SCL:HYSTeresis..................................................................................... 726
SBUS<sb>:I2C:SCL:SOURce......................................................................................... 726
SBUS<sb>:I2C:SCL:THReshold......................................................................................726
SBUS<sb>:I2C:SDA:HYSTeresis.....................................................................................727
SBUS<sb>:I2C:SDA:SOURce......................................................................................... 727
SBUS<sb>:I2C:SDA:THReshold......................................................................................727
SBUS<sb>:I2C:SDA:POSition......................................................................................... 727
SBUS<sb>:I2C:SDA:SCALe............................................................................................728
SBUS<sb>:I2C:POSition.................................................................................................728
SBUS<sb>:I2C:SCALe................................................................................................... 728
SBUS<sb>:I2C:SYMBols................................................................................................ 728
SBUS<sb>:I2C:NEWList.................................................................................................729
SBUS<sb>:I2C:SCL:HYSTeresis <Hysteresis>
Sets a hysteresis value for the clock line.
Suffix:
<sb>
.
1...4, index of the serial bus
Parameters:
<Hysteresis>
Usage: Asynchronous command
Manual operation: See "Threshold" on page 339
SBUS<sb>:I2C:SCL:SOURce SCLSource
Selects the waveform source of the clock line.
Suffix:
<sb>
.
1...4, index of the serial bus
Parameters:
SCLSource C1 | C2 | C3 | C4 | D0 | D1 | D2 | D3 | D4 | D5 | D6 | D7 | D8 | D9
| D10 | D11 | D12 | D13 | D14 | D15 | M1 | M2 | M3 | M4 | M5 |
R1 | R2 | R3 | R4
Usage: Asynchronous command
Manual operation: See "SCL source" on page 339
SBUS<sb>:I2C:SCL:THReshold <Threshold>
Sets a user-defined threshold value for the clock line.
Suffix:
<sb>
.
1...4, index of the serial bus
Parameters:
<Threshold>