Remote control commandsMXO 4 Series
801User Manual 1335.5337.02 ─ 07
Parameters:
<IdParityError> ON | OFF
*RST: ON
Usage: Asynchronous command
Manual operation: See "Error conditions" on page 398
TRIGger:LIN:SYERror <SyncError>
Triggers if a synchronization error occurs.
Available, if TRIGger:LIN:TYPE is set to ERRC.
Parameters:
<SyncError> ON | OFF
*RST: ON
Usage: Asynchronous command
Manual operation: See "Error conditions" on page 398
17.16.6.3 Filter
There are two commands for each parameter, that you can use for defining the LIN
settings.
For example, to set the Frame type =Data > Field =Id >Id value you can use one of the
following commands:
●
SBUS:LIN:FILTer:FRAMe1:FLD1:DMIN 00
Defines the parameter by using the index <m> for the frame number and <n> for
the field number.
●
SBUS:LIN:FILTer:DMIN "Data", "Address", 00
Defines the parameter by using the frame and field name.
SBUS<sb>:LIN:FILTer:CHKall......................................................................................... 802
SBUS<sb>:LIN:FILTer:CLR............................................................................................. 802
SBUS<sb>:LIN:FILTer:INVert...........................................................................................802
SBUS<sb>:LIN:FILTer:RST............................................................................................. 802
SBUS<sb>:LIN:FILTer:BIT...............................................................................................803
SBUS<sb>:LIN:FILTer:FRAMe<fr>:FLD<fl>:BIT................................................................ 803
SBUS<sb>:LIN:FILTer:DMAX.......................................................................................... 803
SBUS<sb>:LIN:FILTer:FRAMe<fr>:FLD<fl>:DMAX............................................................ 803
SBUS<sb>:LIN:FILTer:DMIN........................................................................................... 803
SBUS<sb>:LIN:FILTer:FRAMe<fr>:FLD<fl>:DMIN............................................................. 803
SBUS<sb>:LIN:FILTer:DOPerator.................................................................................... 804
SBUS<sb>:LIN:FILTer:FRAMe<fr>:FLD<fl>:DOPerator...................................................... 804
SBUS<sb>:LIN:FILTer:ERENable.................................................................................... 804
SBUS<sb>:LIN:FILTer:ERRor<n>:ENABle........................................................................ 804
SBUS<sb>:LIN:FILTer:FIENable...................................................................................... 804
SBUS<sb>:LIN:FILTer:FRAMe<fr>:FLD<fl>:ENABle.......................................................... 804
SBUS<sb>:LIN:FILTer:FRENable.....................................................................................805
Protocols