Parameters:
<RampSymmetry> Range: 0 to 100
Increment: 1
*RST: 50
Default unit: %
Usage: Asynchronous command
Manual operation: See "Symmetry" on page 440
WGENerator<wg>:MODulation:PWM[:FUNCtion] <SignalType>
Selects the type of the modulating signal for PWM modulation.
Suffix:
<wg>
.
1...2, index of the waveform generator
Parameters:
<SignalType> SINusoid | SQUare | RAMP
*RST: SINusoid
Usage: Asynchronous command
Manual operation: See "Signal type" on page 439
WGENerator<wg>:MODulation:TYPE <ModulationType>
Selects the modulation type, which defines how the carrier signal is modified.
Suffix:
<wg>
.
1...2, index of the waveform generator
Parameters:
<ModulationType> NONE | AM | FM | PWM | ASK | FSK
*RST: AM
Usage: Asynchronous command
Manual operation: See "Modulation type" on page 439
17.18.1.3 ARB settings
WGENerator<wg>:ARBGen:NAME..................................................................................871
WGENerator<wg>:ARBGen:OPEN.................................................................................. 871
WGENerator<wg>:ARBGen:RUNMode............................................................................ 871
WGENerator<wg>:ARBGen:RUNSingle........................................................................... 871
WGENerator<wg>:ARBGen:SAMPles?............................................................................ 872
WGENerator<wg>:ARBGen:SRATe................................................................................. 872
WGENerator<wg>:ARBGen[:SOURce].............................................................................872
Waveform generator (option R&S
MXO4-B6)