EasyManua.ls Logo

Rohde & Schwarz PR100 - Page 141

Rohde & Schwarz PR100
282 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
R&S PR100 User Manual
MEMory
. :CONTents <mem_loc>, <mem_paras>|<packed_struct>
Loading a memory location. The memory contents can be specified in two
ways:
<mem_paras> A comma-separated list of parameters in a specific order.
<packed_struct> A device specific binary format, provided as a Block Data.
Parameters:
<mem_loc> CURRENT|0...1023|NEXT|RX
<mem_paras> <F>, <THR>, <DEM>, <BW>, <ANT>, <ATT>, <ATTA>,
<SQUC>, <AFC>, <ACT>
<packed_struct> Block Data with the following payload
The definition of the parameters is as follows:
Parameter C Data-Type Description
<F> unsigned long
long
frequency in Hz (see SENS:FREQ:CW).
Note that a “long” type is not large
enough, since frequencies can be larger
than 4 GHz.
<THR> signed short squelch threshold in dBVV (see
OUTP:SQU:THR)
<DEM> unsigned short type of demodulation (see SENS:DEM)
packed_struct: See Table 24 in Section
12.2
<BW> unsigned long Bandwidth in Hz (see SENS:BWID).
<ANT> unsigned char antenna number (see ROUT:SEL)
packed_struct: 0...99
<ATT> unsigned char attenuator (see INP:ATT:STAT)
packed_struct: 0 = OFF, 1 = ON
<ATTA> unsigned char Always 0 = OFF. This field was kept for
compatibility with EB200.
<SQUC> unsigned char squelch function (see OUTP:SQU:STAT)
packed_struct: 0 = OFF, 1 = ON
<AFC> unsigned char AFC function (see (SENS:FREQ:CW:AFC)
packed_struct: 0 = OFF, 1 = ON
<ACT> unsigned char include the memory in a memory scan
packed_struct: 0 = OFF, 1 = ON