IFPAN frequency span FREQ:SPAN 10M 10k 10M Hz + -
FSCAN frequency start FREQ:STAR 88M 9K 100G Hz + -
FSCAN frequency stop FREQ:STOP 108M 9K 100G Hz + -
Detector functions concurrent FUNC:CONC 1 - - bool + -
Detector functions off FUNC:OFF (1) - - string + -
Detector functions off counter FUNC:OFF:COUN 3 - - - + -
Detector functions on FUNC:ON “” - - string + -
Detector functions on counter FUNC:ON:COUN 0 - - - + -
Gain control GCON 50 -30 110 dB + -
Gain control mode GCON:MODE AUTO - - enum + -
MSCAN current mem location MSC:CHAN 0 - - - + -
MSCAN control mechanisms off MSC:CONT:OFF “” - - string + -
MSCAN control mechanisms on MSC:CONT:ON STOP:SIGN - - string + -
MSCAN number of scans MSC::COUN INF 1 1000/INF - + -
MSCAN scan direction MSC:DIR UP - - enum + -
MSCAN dwell time MSC:DWEL 0.5 0.0 60.0/INF s + -
MSCAN hold time MSC:HOLD:TIME 0.0 0.0 60.0 s + -
MSCAN memory list start MSC:LIST:STAR 0 - - - + -
MSCAN memory list stop MSC:LIST:STOP 99 - - - + -
PSCAN number of scans PSC:COUN INF 1 1000/INF + -
PSCAN FFT bin width PSC:STEP 12.5k 125 100k Hz + -
Oscillator ext reference frequency ROSC:EXT:FREQ - - - Hz + -
Oscillator int reference frequency ROSC:INT:FREQ - - - Hz + -
Oscilator source ROSC:SOUR INT - - enum + -
FSCAN control mechanisms off SWE:CONT:OFF “” - - string + -
FSCAN control mechanisms on SWE:CONT:ON STOP:SIGN - - string + -
FSCAN number of scans SWE::COUN INF 1 1000/INF - + -
FSCAN scan direction SWE:DIR UP - - enum + -
FSCAN dwell time SWE:DWEL 0.5 0.0 60.0/INF s + -
FSCAN hold time SWE:HOLD:TIME 0.0 0.0 60.0 s + -
FSCAN step SWE:STEP 100k 1 1G Hz + -
13.8 STATus subsystem
Item Command: [STAT:] Factory
Default
Min Max Unit *RST PWR
ON
operation condition section OPER:COND 0 0 65535 value - -
operation enable section OPER:ENAB 0 0 65535 value - +
operation event section OPER:EVEN 0 0 65535 value - +
operation negative transition OPER:NTR 0 0 65535 value - +
operation positive transition OPER:PTR 65535 0 65535 value - +
error queue QUE 0,”No error” - - string - +
13.9 SYSTem subsystem
Item Command: [SYST:] Factory
Default
Min Max Unit *RST PWR
ON
audio balance AUD:BAL 0.0 -0.5 0.5 - + -
audio volume AUD:VOL 0.30 0.00 1.00 - + -
audio output AUD:OUTP - - - - + -
audio digital AF mode AUD:REM:MOD - - - - + -
beep volume BEEP:VOL 0.30 0.00 1.00 - + -
LAN MAC address COMM:LAN:ETH mac address - - - - -
LAN submask COMM:LAN:SUBM 255.255.255.0 - - - - -
LAN socket address COMM:SOCK:ADDR 172.17.75.1 - - - - -
LAN DHCP protocol enabled COMM:SOCK:DHCP 0 - - bool - -
LAN socket port COMM:SOCK:PORT 5555 0 65535 16 bit - -
keyclick volume KCL:VOL - - - - - -
userinterface manual state KLOC - - - - - -
language LANG:CAT - - - - - -
password protection PASS:STAT - - - - - -
power off time POW:AUTO:OFF:TIME - - - - - -
13.10 TRACe subsystem
Item Command: [TRAC:] Factory
Default
Min Max Unit *RST PWR
ON
data catalog CAT - - - - - -
data memory fill mode FEED:CONT - - - - - -