R&S FSL CONFigure:BTOoth Subsystem (BLUETOOTH, K8)
1300.2519.12 6.365 E-11
Characteristics
RST value: 10%
SCPI: device–specific
Mode
BT
CONFigure:BTOoth:RTPower:GAVerage:STOP
This command sets the stop time for the power measurement of the GFSK sections of the
packet.
Note: This command is only available with active Relative Transmit Power measurement (see
CONFigure:BTOoth:MEASurement command).
Parameter
0 to 100%
Example
CONF:BTO:RTP:GAV:STOP 80
Sets the stop time for the power measurement of the GFSK sections of the packet.
Characteristics
RST value: 90%
SCPI: device–specific
Mode
BT
CONFigure:BTOoth:SWEep:COUNt
This command defines the number of sweeps for the currently selected Bluetooth
measurement. This number will be started as a "single sweep". With trace mode setting
clear/write (CONFigure:BTOoth:TRACe<1...6>:MODE) the measurement results will be
calculated for each sweep and taken into account for the calculation of minimum, maximum and
average values. For the remaining trace settings (AVER, MAXH, MINH) the measurement
results will be calculated from the resulting trace. In average mode the value 0 defines the
sliding average of the measurement data over 10 sweeps.
Note: The setting is valid only for the currently active measurement (see
CONFigure:BTOoth:MEASurement command) and independent of the other
Bluetooth measurements.
Parameter
0 to 32767
Example
CONF:BTO:MEAS OPOW
Activates the Output Power measurement.
INIT:CONT OFF
Selects single sweep operation.
CONF:BTO:SWE:COUN 20
Sets the number of sweeps to 20.
INIT;*OPC
Starts a sweep with synchronization.