R&S FSL CALCulate Subsystem (CATV, K20)
1300.2519.12 6.461 E-11
CALCulate:DTV:UNIT:POWer Subsystem (CATV, K20)
The CALCulate:DTV:UNIT:POWer subsystem sets the unit for the measurements for digital TV
measurements.
Commands of the CALCulate:DTV:UNIT:POWer Subsystem
CALCulate<1|2>:DTV:UNIT:POWer:EPATtern
CALCulate<1|2>:DTV:UNIT:POWer:EVMPeak
CALCulate<1|2>:DTV:UNIT:POWer:EVMRms
CALCulate<1|2>:DTV:UNIT:POWer:MERPeak
CALCulate<1|2>:DTV:UNIT:POWer:MERRms
CALCulate<1|2>:DTV:UNIT:POWer:EPATtern
This command defines the unit of the Echo Pattern measurement.
The numeric suffixes <1|2> are irrelevant.
Parameter
s | m
Example
CALC:DTV:UNIT:POW:EPAT M
Sets the unit for the Echo Pattern measurement to meters.
Characteristics
RST value: s (seconds)
SCPI: device–specific
Mode
CATV
CALCulate<1|2>:DTV:UNIT:POWer:EVMPeak
This command defines the unit of the error vector magnitude peak in the Overview / Modulation
Errors measurement.
The numeric suffixes <1|2> are irrelevant.
Parameter
DB | PCT
Example
CALC:DTV:UNIT:POW:EVMP DB
Sets the unit for the error vector magnitude peak to dB.
Characteristics
RST value: % (PCT)
SCPI: device–specific
Mode
CATV