R&S FSL CALCulate Subsystem (CDMA, K82)
1300.2519.12 6.599 E-11
CALCulate:LIMit:ESPectrum Subsystem (CDMA, K82)
The CALCulate:LIMit:ESPectrum subsystem defines the limit check for thr Spectrum Emission Mask.
Commands of the CALCulate:LIMit:ESPectrum Subsystem
– CALCulate<1|2>:LIMit<1...8>:ESPectrum:MODE
– CALCulate<1|2>:LIMit<1...8>:ESPectrum:RESTore
– CALCulate<1|2>:LIMit<1...8>:ESPectrum:VALue
CALCulate<1|2>:LIMit<1...8>:ESPectrum:MODE
This command activates or deactivates the automatic selection of the limit line in the Spectrum
Emission Mask measurement.The numeric suffix at CALCulate<1|2> specifies the
measurement window. The numeric suffix at LIMit<1...8> is irrelevant for this command.
Parameter
AUTO The limit line depends on the measured channel power.
MANUAL One of the three specified limit lines is set. The selection is made with the
CALCulate<1|2>:LIMit<1...8>:ESPectrum:VALue command.
Example
INST:SEL BC2K
Activates the CDMA2000 BTS Analyzer option.
INIT:CONT OFF
Selects single sweep.
CONF:CDP:BCL 1
Select band class 1, 1900 MHz
CONF:CDP:MEAS ESP
Selects Spectrum Emission Mask measurement.
CALC:LIM:ESP:MODE AUTO
Activates automatic selection of the limit line.
INIT;*WAI
Starts measurement with synchronization.
CALC:LIM:FAIL?
Queries result of the limit check.
Characteristics
RST value: AUTO
SCPI: device-specific
Mode
CDMA
CALCulate<1|2>:LIMit<1...8>:ESPectrum:RESTore
This command restores the predefined limit lines for the Spectrum Emission Mask
measurement. All modifications made to the predefined limit lines are lost and the factory–set
values are restored.
The numeric suffix at CALCulate<1|2> specifies the measurement window. The numeric suffix
at LIMit<1...8> is irrelevant for this command.
This command is an event and therefore has no *RST value and no query.