R&S FSL 1xEV-DO BTS Analyzer (Option K84)
1300.2519.12 4.371 E-11
PN Offset
Set the PN (Pseudo Noise) offset. The PN offset is used to distinguish the individual base
stations in a 1xEV-DO network.
The PN offset determines the offset in the circulating PN sequence in multiples of 64 chips with
reference to the event second clock trigger.
Although the parameter is always available, it only has a function in External trigger mode.
Remote: CDP:PNOF 512
Channel Table Settings
Opens the Demod Settings dialog box and corresponding softkey submenu. The dialog box
also displays the available predefined channel tables.
Predefined channel tables are a way to customize measurements. The RECENT channel table
contains the last configuration used before switching from Auto Search to Predefined. The
DO16QAM, DO8PSK, DO_IDLE and DOQPSK channel tables are included in the option per
default and are configured according to the standard. For details on the predefined channel
tables refer to Predefined Channel Tables on page 4.303. In addition, you can create new
channel tables to be used in measurements. For details refer to the New softkey.
In the Demod dialog box, the following parameters can be modified:
Channel Table
Inactive Channel Threshold
Available Channel Tables