WLAN TX Measurements (Option K91 / K91n) R&S FSL
1300.2519.12 4.422 E-11
Equal Burst Length (Demod Settings dialog box)
Activates or deactivates the burst selection for measurement analysis according to the range or
specific number of data symbols/bytes.
Standard State Description
IEEE 802.11a, j, n On Only bursts with exactly the number of symbols specified in the
Data Symbols field are considered for measurement analysis.
Off Only bursts within the range of data symbols specified by the
Min Data Symbols and Max Data Symbols fields are
considered for measurement analysis.
IEEE 802.11b, g
(Single Carrier)
On Only bursts with exactly the number of data bytes or duration
specified in the Payload Length field are considered for
measurement analysis.
Off Only bursts within the range of data bytes or duration specified
by the Min Payload Length and Max Payload Length fields
are considered for measurement analysis.
IEEE 802.11g
(OFDM)
On Only bursts with exactly the number of data symbols or
duration specified in the Payload Length field are considered
for measurement analysis.
Off Only bursts within the range of data symbols or duration
specified by the Min Payload Length and Max Payload
Length fields are considered for measurement analysis.
Remote: DEM:FORM:BAN:SYMB:EQU ON
Remote: DEM:FORM:BAN:DBYTes:EQU ON
Remote: DEM:BAN:DUR:EQU ON (PVT)
Data Symbols (Demod Settings dialog box, IEEE 802.11a, j, n)
Specifies the number of data symbols of a burst to be considered in measurement analysis. This
field is only available if the Equal Burst Length option is activated.
Remote: DEM:FORM:BAN:SYMB:MIN 16
Min Data Symbols (Demod Settings dialog box, IEEE 802.11a, j, n)
Specifies the minimum number of data symbols of a burst to be considered in measurement
analysis. This field is only available if the Equal Burst Length option is deactivated.
Remote: DEM:FORM:BAN:SYMB:MIN 16
Max Data Symbols (Demod Settings dialog box, IEEE 802.11a, j, n)
Specifies the maximum number of data symbols of a burst to be considered in measurement
analysis. This field is only available if the Equal Burst Length option is deactivated.
Remote: DEM:FORM:BAN:SYMB:MAX 1300