EasyManua.ls Logo

Rohde & Schwarz R&S FSL3 - Page 617

Rohde & Schwarz R&S FSL3
1734 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
WLAN TX Measurements (Option K91 / K91n) R&S FSL
1300.2519.12 4.432 E-11
Spectrum Mask (IEEE 802.11b, g – Single Carrier),
Spectrum IEEE/ETSI (IEEE 802.11a, g, j, n – OFDM)
Sets the Spectrum Mask result display.
T
his result display shows power against frequency. The span of the results is 100 MHz for IEEE
and 500 MHz for ETSI around the specified measurement frequency. A limit line representing
the spectrum mask specified for the selected standard is displayed and an overall pass/fail
status is displayed for the obtained results against this limit line. The number of sweeps is set in
the General Settings dialog box, Sweep Count field. If the measurement is performed over
multiple sweeps both a max hold trace and an average trace are displayed.
Remote: CONF:BURS:SPEC:MASK
Remote: CONF:BURS:SPEC:MASK:SEL ETSI
Spectrum FFT
Sets the Spectrum FFT result display.
This result display shows the Power vs Frequency results obtained from a FFT performed over
the range of data in the Magnitude Capture Buffer which lies within the gate lines.
Remote: CONF:BURS:SPEC:FFT

Table of Contents